This page explains how to power the OV20i system safely using standard wall outlets, and what adapters or supplies are compatible.


Yes — Wall Power Is Allowed

You can power the OV20i using a wall outlet, as long as you use a compatible 24V DC power supply.

RequirementSpec
Voltage Range19–24 VDC
Power Input PortM12 A-Coded 17-pin connector
Current Draw~1.5A max
GroundingRequired for I/O functionality

Overview recommends the following accessory:

Part NameDetails
24V DIN-Rail Power SupplyConverts 110–240 VAC to 24V DC
M12 Power Cable17-pin A-coded with flying leads or terminals
MountingCan be DIN-mounted in control panel
note

See the full list of accessories in Recommended Accessories.


Setup Instructions

  1. Connect M12 Power Cable

    → Connect pins 13 & 14 to +24 VDC

    → Connect pins 5 & 6 to GND

  2. Use Industrial 24V Adapter

    → Rated for ≥36 W output

    → Must be regulated and isolated

  3. Ground DIO GND if using triggers or outputs

    → Pin 7 (DIO GND) should be tied to system GND


⚠️ Do Not Use:

⚠️ Not RecommendedWhy Not
USB-C PortNot supported or used on the OV20i
POE InjectorsOV20i does not support Power over Ethernet
Unregulated 24V SourcesMay cause brownout, instability, or damage

Best Practices

  • ✅ Use Overview-approved power supplies or industrial-grade adapters
  • ✅ Ensure proper fuse protection (1–2A slow blow fuse suggested)
  • ✅ Confirm power polarity before applying current
  • ✅ Secure connections with locking M12 screw ring